• According to
- Performance Level (PL) d and category 3 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
- Safety Integrity Level (SIL 2) to IEC/EN 61508
• Single channel operation
• Output: max. 4 NO contacts
• AC 230 V model with galvanic separation
• LED indicator for channel 1 / 2 and state of operation
• Short circuit detection between terminal Y1 and common
• Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
• as option with pluggable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• Width 22.5 mm